What is the role of the manufacturer?(1)
(2) Parallel connection of redundant hot backup. Connecting the output terminals of the same module through diodes in parallel can enhance the output capability and improve the reliability of the power supply system. In principle, if it cooperates with the corresponding output alarm circuit, put the module on the busbar that can be removed, so that the faulty module can be replaced in time. There is no limit to the number of modules connected in parallel in this way. D is generally a Schottky diode.
(3) Series expansion. Connecting the output terminals of the same module in series can double the output voltage and increase the power accordingly, and the series output terminals must be connected with diodes for protection.
For DCDC module power supply products with TRIM or ADJ (adjustable) output pins, the output voltage can be adjusted within a certain range through resistors or potentiometers, manufacturer and the general adjustment range is ±10%.
For the TRIM output pin, the center of the output potentiometer and the center TRIM are all connected to +S, -S in the pin module, and the other two ends are connected to +S, -S respectively. There is no +S, and the -S ends receive the positive and negative outputs of the corresponding main circuit respectively (+S is connected to +Vin, -S is connected to -Vin), and then adjust the potentiometer. The resistance of the potentiometer is generally 5~10kΩ.
manufacturer The ADJ output pins are divided into input adjustment and output adjustment. Output trim and output trim. The adjustment method of the TRIM pin is the same. When one end of the potentiometer is connected to the center, the output voltage can only increase the output voltage, and the other end is connected to the ground of the input.